LogicPLUS-S Two-Wire Controller
8
8
Mounting the controller...........When selecting the controller installation location,
When mounting the LogicPLUS-S indoors, notice the “keyhole” shaped mounting slot
as well as 2 mounting holes on the back of the controller. Use the template provided to locate mount-
ing screw locations. Remove the four face plate screws and two lower panel screws to access enclo-
sure mounting screws. To attach to wall studs, use a #10 screw, leaving 1/4” of the shank exposed to
slip into the “keyhole” slot. To additionally secure the controller, drive additional screws through the
bottom mounting holes into the stud or cross bracing.
use the same procedure as above. When attaching
the controller to hollow walls, masonry, or cinder blocks, use appropriate toggle bolts, masonry shields
or compression drive bolts. For additional weatherproong, run a silicon bead around the case be-
tween the controller and the wall. It is also recommended to ll mounting holes with silicon as well, to
prevent water or insects from entering the controller.
Unscrew the LogicPLUS-S bottom terminal plate and route the eld wires (one to four sets) through
the hole at the bottom of the controller. Secure each 2-wire run under the appropriate terminal on the
terminal strip labeled If using multiple outputs, keep each 2
wire set independent. “Line 1” with output with or any
other combination. It is strongly suggested to use different colored wires for each wire used.
To easily test for communication and wire integrity, connect each receiver to the eld wiring at each
planned location. It is not necessary for receiver to be attached to solenoid/valve for test, but O.K. if
already connected. Do not allow black receiver wires to touch each other (short or ground) when test-
ing. Manually sequence controller through each station number for minimum of 30 seconds, checking
each activated receiver in the eld for a continuously activated bright LED light on each receiver. A
continuously activated bright LED light on receiver during station activation conrms satisfactory com-
munication.
Please read the entire operational manual before installing and programming the LogicPLUS-S
Controller.