LogicPLUS-S Two-Wire Controller
23
Position 10 | | Semi / Manual / Program / Master Clear | | Current Monitoring Special Function
- use set 1 to choose the program you want to activate for one cycle, use set 2 to activate that
program ON. Leave the dial in number 10 position. 
Set 5 will activate the Current Monitoring feature.


 — Press set 3 to activate manual mode the display will change, use set 1 to choose the
specic valve number to be operated manually for a predetermined time, use set 2 to set amount of
hours to run, use set 3 to set amount of minutes, use set 4 to tell the controller whether or not you
want the master valve A, B, C, and pump on during this manual operation. Valve will immediately be
activated for that period of time. Use set 5 to activate the Current Monitoring feature. Leave the dial
in number 10 position.  At the conclusion, the controller
will go back to “RUN” mode without turning the Dial back to the “RUN” position. You can activate up
to 8 valves at the same time in manual mode.


