Hit-products LogicPLUS S 42/128 Manual de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 45
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
LogicPLUS-S Two-Wire Controller
22
22
Position 9 | | Test Cycle | | Function Button - Short Test
Use set 1 to set run times in minutes, use set 2 to set run time of seconds for test cycle, set 3 has no
response, and use set 4 to select valve range to test, display will change, use set 1 or set 2 to select
valve range start and end, use set 3 to select Master A, B or C if required, use set 4 to start test cycle,
press set 4 again to stop test cycle.
The controller will immediately run each valve in sequence for valve range and predetermined run
time for visual review of the system operation.


Use set 5 Function Button to perform a short test.

This feature to be used for troubleshooting. See page 32.